PFA Insulated Type E Thermocuple Extension Cable

Product Details
Customization: Available
Certification: ISO9001, RoHS
Conductor Material: Nicr/Constantan
Still deciding? Get samples of US$ 1/Meter
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
15
Year of Establishment
2012-02-06
  • PFA Insulated Type E Thermocuple Extension Cable
  • PFA Insulated Type E Thermocuple Extension Cable
  • PFA Insulated Type E Thermocuple Extension Cable
  • PFA Insulated Type E Thermocuple Extension Cable
  • PFA Insulated Type E Thermocuple Extension Cable
  • PFA Insulated Type E Thermocuple Extension Cable
Find Similar Products

Basic Info.

Model NO.
Type E Cable
Sheath Material
PFA
Plug Type
Depend on Customer
Insulating Materials
PFA
Transport Package
Roll/Wooden Case
Specification
0.3mm-3.2mm
Trademark
Ualloy
Origin
China
HS Code
9025900090
Production Capacity
5000000

Product Description

Product Description
 PFA Insulated Type E Thermocuple Extension Cable
 
NiCr-NiSi (Type K) thermocouple finds the widest use in all basemetal thermocouple, at temperature above 500 °C.The main chemical composition of positive leg NiCr (KP) are Ni≈90% and Cr≈10%; negative leg NiSi (KN) are Ni≈97% and Cr≈3%. The operating temperature range is -200~1300°C(for short term) and 0~1100°C( for long term) .
Type K thermocouple has strong resistance to oxidation than other base metal thermocouples. It has high EMF against Platinum 67, excellent temperature accuracy, sensitivity and stability, with a low cost. It is recommended for oxidizing or inert atmospheres, but cannot be used directly in the following cases:
              (1) Alternatively oxidizing and reducing atmosphere,
              (2) Atmosphere with sulphur gases
              (3) Long time in vacuum
              (4) Low oxidizing atmosphere such as hydrogen and carbon monoxide atmosphere
 
Type K Temperature Range:
  • Thermocouple grade wire, -200~1300ºC(for short term) and 0~1100ºC( for long term)
  • Extension wire, 32 to 392F (0 to 200C)
 
Type K Accuracy :
 
Standard: +/- 1.5C or +/-0.4%t
 
Working temperature:
 
The products is manufactured according to the standards of GB/T4989-1994 "Compensating Wire for
Thermocouples" and JB/T7495-1994 "Compensating Cable for Thermocouples".
       This kind of products are mainly used as the connect wire in the automatic measure instruments in the
electronic power industry, chemical industry, petroleum industry, metallurgy industry and national
defense industry, etc.
       More details about the product:
 
Item No. E-PA-PA-0.5R
  Conductor Material   +NiCr, -CuNi
  Conductor Dia 0.35mm*7/2
   Insulation material PFA
   Insulation color + brown, -white
  Cable Construction   Parallel
Inner Shielding material /
  Jacket material PFA
   Jacket color white
  Outer Shielding Material  /
Ground wire /
 Cable Dielectric Test   DC.500v
 Net weight 25kg/km

 
   
   
     
     
     
     
     
     

 

Send your message to this supplier