Customization: | Available |
---|---|
Type: | Insulated |
Conductor Type: | Solid |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Types | K |
Conductor Material | +Chromel, -Alumel |
Insulation Material | Polyvinyl |
Jacket | Fiberglass |
Conductor diameter | 0.2mm to 1.5mm |
Temperature range | -200ºC-1200ºC |
Standard | IEC584-2 |
Type ,designation and kind of thermocouples
Type |
Designation |
Thermocouple |
Thermocouple Grade ID |
SC and RC |
Copper-copper nickel 0.6 compensated compensating lead |
Platonic-rhodium 10-platinum Thermocouple |
S and R |
Platonic-rhodium 13-platinum thermocouple |
|||
KCA |
Iron-copper nickel 22 Compensated Compensating Lead |
Nickel-chromium nickel thermocouple |
K |
KCB |
Iron-copper nickel 40 compensated compensating lead |
||
KX |
Nickel-chromium 10-nickel 3 prolonged compensating Lead / compensating cable |
||
NC |
Iron-copper nickel 18 compensated compensating lead |
Nickel-chromium silicon-nickel thermocouple |
N |
NX |
Nickel-chromium 14 silicon-nickel 4 prolonged compensating lead / compensating cable |
||
EX |
Nickel-chromium 10-nickel 45 prolonged compensating lead / compensating cable |
Nickel-chromium-cupronickel thermocouple |
E |
JX |
Iron-copper nickel 45 prolonged compensating lead / compensating cable |
Iron-constantan thermocouple |
J |
TX |
Iron-nickel-chromium 45 prolonged compensating lead / compensating cable |
Copper-constantan thermocouple |
T |